While AC locos need only 6 or 8 indication lamps,the WCAM-1 loco has 12 indication lamps on the driver's desk.Also,they are located below the switchboard rather than beside it as in AC locos.A brief explanation: LSS-To indicate line supply;extinguished when either AC or DC is available. LSDJ/DS-To indicate status of DJ/DS;Extinguished when DJ/DS is closed. LSMA-Extinguished when proper output voltage is available from the Motor-Alternator set. LSQ-Signal lamp to indicate overload in Traction Motors. LSRSI-Signal lamp to indicate over-voltage/imbalance in Silicon Rectifier blocks. LSRN-Signal lamp to indicate resistance notches in DC line working. LSGR/SC-Lights up when the Tap-Changer(GR-in AC line)/Servo-Controller(SC in DC line)reaches zero position. LSP-Indicates wheel slip LSTR-This lamp flickers when transition takes place(between 21 and 22 notch)from series to series-parallel during DC line working. LSCHBA-Extinguished when battery charger is working. LSQCBS-Signal lamp to indicate earth fault in power circuit during DC line working. LSR-1-To indicate R-1 contactor open during DC line working. (Khalid Kagzi)